Stone wool panel with aluminium foil membrane to one side 30 dB rating requires two layers of panels, each 30mm thick, placed back to back
Back
Other performances
Direct Sound Insulation
Rw = 21-30
Sound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.
Reaction To Fire
C-s1,d0, (21 dB) A1 (30 dB) (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Humidity And Sag Resistance
Up to 100% RH
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Hygiene
Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment
Fully recyclable stone wool
Indoor Environment
A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Back
Sound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back
Full range
Dimensions (mm)
Thickness (mm)
Weight (Kg/m2)
Min. suspension height (mm)
Recommended installation system
1200 x 1000
60
6.90
0
Tile details
Minimum installation height
0 mm
Packaging
Pieces Per Pack
Area Per Pack
m2
1200 x 1000
65
4.70
0
Tile details
Minimum installation height
0 mm
Packaging
Pieces Per Pack
Area Per Pack
m2
Soundstop 30 dB: The actual thickness equals 2x30 mm
We provide customers with a complete acoustic ceiling system offering, combining sound absorbing ceiling tiles and wall panels with suspension grid systems and accessories.