Rockfon® Soundstop

Acoustic barriers which reduce noise transfer in ceiling and floor plenums
Back
Back

Other performances

Room To Room Sound Insulation Room To Room Sound Insulation 0
Room-to-room sound insulation Dn,f,w (C;Ctr) is measured in accordance with ISO 10848-2.
Direct Sound Insulation Direct Sound Insulation Rw = 21-30
Sound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.
Reaction To Fire Reaction To Fire A1 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Recyclability Recyclability Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Back
Room-to-room sound insulation Dn,f,w (C;Ctr) is measured in accordance with ISO 10848-2.
Back
Sound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back

Full range

Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
1200 x 1000 60 6.90 0

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack
Area Per Pack m2
1200 x 1000 65 4.70 0

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack
Area Per Pack m2

Soundstop 30 dB: The actual thickness equals 2x30 mm

Back

Sound absorption details

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack
Area Per Pack m2
Back

Sound absorption details

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack
Area Per Pack m2
Back

Downloads

documents

 

 

pdf
Rockfon® Soundstop | Datasheet
Rockfon® Soundstop | Datasheet

pdf
DoP-RFN-0013-R003-01 - Rockfon® Soundstop
DoP-RFN-0013-R003-01 - Rockfon® Soundstop

pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
DoP-RFN-0012-R003-A1-01 - Rockfon® Soundstop
DoP-RFN-0012-R003-A1-01 - Rockfon® Soundstop

pdf
Back