Sound absorption details

Practical Sound Absorption Coefficient (αp)
Edge Thickness Suspension height 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz Sound absorption class αw NRC
A24, E24 20/25mm 200mm 0.50 0.80 1.00 0.95 1.00 1.00 A 1.00 0.95
X 22mm 200mm 0.60 0.85 0.90 0.90 1.00 1.00 A 0.95 0.90

Sound absorption is measured in accordance with ISO 354.

Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Back
Sound curve
Back
Sound curve

Other performances

Reaction To Fire Reaction To Fire A1 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Light reflection and light diffusion Light reflection and light diffusion 85%
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH.
No visible deflection in high humidity
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Surface Durability Surface Durability Enhanced durability and dirt resistance.
The surface of some ROCKFON products is specially treated to provide enhanced durability and dirt resistance.
Cleaning Cleaning Vacuum, Damp cloth, Steam cleaning (twice a year), Chemical resistance: resistant to diluted solutions of ammonia, chlorine, quaternary ammonium and hydrogen peroxide
Vacuum: The surface can be vacuum cleaned with a soft brush attachment. Damp cloth: The surface can be cleaned using a damp cloth or sponge with a slightly alkaline detergent (pH between 7 and 9) without alcohol, ammonia or chlorine. This may render the surface slightly shinier, so we recommend cleaning the entire surface evenly.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Microbiological class M1 fulfilling the requirements of Zone 4 (very high risk) defined by NF S 90-351:2013. Tested with:
- Methicillin Resistant Staphylococcus Aureus (MRSA)
- Candida Albicans
- Aspergillus Brasiliensis
The bactericidal and fungicidal effect of dry steam cleaning meets the requirements of NF EN 14561 (> 5 log10) and NF EN 14562 (> 4 log10), meaning the disinfection is very effective.
Clean Room Classification Clean Room Classification 3
Clean room classification is measured in accordance with ISO 14644-1.
Bacteriological Class M1, NF S 90-351:2013
Environment Environment Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
The surface of some ROCKFON products is specially treated to provide enhanced durability and dirt resistance.
Back
Vacuum: The surface can be vacuum cleaned with a soft brush attachment. Damp cloth: The surface can be cleaned using a damp cloth or sponge with a slightly alkaline detergent (pH between 7 and 9) without alcohol, ammonia or chlorine. This may render the surface slightly shinier, so we recommend cleaning the entire surface evenly.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Microbiological class M1 fulfilling the requirements of Zone 4 (very high risk) defined by NF S 90-351:2013. Tested with:
- Methicillin Resistant Staphylococcus Aureus (MRSA)
- Candida Albicans
- Aspergillus Brasiliensis
The bactericidal and fungicidal effect of dry steam cleaning meets the requirements of NF EN 14561 (> 5 log10) and NF EN 14562 (> 4 log10), meaning the disinfection is very effective.
Back
Clean room classification is measured in accordance with ISO 14644-1.
Back
Back
Back
Back

Full range

Edge Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
A24 1200 x 600 20 2.30 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 12
Area Per Pack 8.64 m2
A24 1800 x 600 20 2.30 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 12
Area Per Pack 12.96 m2
A24 2100 x 600 25 2.70 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 11
Area Per Pack 13.86 m2
A24 2400 x 600 25 2.70 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 10
Area Per Pack 14.40 m2
A24 600 x 600 20 2.30 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 24
Area Per Pack 8.64 m2
E24 1200 x 600 20 2.80 60

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 60 mm

Packaging

Pieces Per Pack
Area Per Pack m2
E24 600 x 600 20 2.80 60

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 60 mm

Packaging

Pieces Per Pack
Area Per Pack m2
X 1200 x 600 22 3.70 66

Sound absorption details

αw 0.95
NRC 0.90
Sound absorption class A

Tile details

Minimum installation height 66 mm

Packaging

Pieces Per Pack 10
Area Per Pack 7.20 m2
X 600 x 600 22 3.70 66

Sound absorption details

αw 0.95
NRC 0.90
Sound absorption class A

Tile details

Minimum installation height 66 mm

Packaging

Pieces Per Pack 10
Area Per Pack 3.60 m2

MS = Minimum suspension
MS easy access = Minimum suspension - tiles demountable
Rockfon System MediCare T24 A, E Class B (not ECR) and Rockfon System T24 X / T24X DLC can only be used when cleaning with aggressive chemicals or disinfectants is not required.

Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 12
Area Per Pack 8.64 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 12
Area Per Pack 12.96 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 11
Area Per Pack 13.86 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 10
Area Per Pack 14.4 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 24
Area Per Pack 8.64 m2
Back

Sound absorption details

Tile details

Minimum installation height 60 mm
Easy access -

Packaging

Pieces Per Pack
Area Per Pack m2
Back

Sound absorption details

Tile details

Minimum installation height 60 mm
Easy access -

Packaging

Pieces Per Pack
Area Per Pack m2
Back

Sound absorption details

Tile details

Minimum installation height 66 mm
Easy access -

Packaging

Pieces Per Pack 10
Area Per Pack 7.2 m2
Back

Sound absorption details

Tile details

Minimum installation height 66 mm
Easy access -

Packaging

Pieces Per Pack 10
Area Per Pack 3.6 m2
Back

Downloads

documents

 

 

pdf zip
Rockfon MediCare® Plus | Datasheet
Rockfon MediCare® Plus | Datasheet

pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
DoP-RFN-0122-041-5 - Rockfon MediCare® Plus
DoP-RFN-0122-041-5 - Rockfon MediCare® Plus

pdf
Rockfon® MediCare® Plus | BIM file
Rockfon® MediCare® Plus | BIM file

zip
Back