Rockfon VertiQ®

Attractive and impact resistant, highly sound-absorbent acoustic wall panels (Class A) suitable for class rooms, sports activity areas and offices
Back

Case studies featuring Rockfon VertiQ®

1/13
Back

Other performances

Reaction To Fire Reaction To Fire A2-s1,d0 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Light reflection and light diffusion Light reflection and light diffusion White 72% Lightgrey 61% Grey 33% Black 5%
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Cleaning Cleaning Vacuum
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment Environment Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Impact Resistance Impact Resistance Rockfon VertiQ C mounted in Rockfon System VertiQ C Wall has been tested for impact resistance in accordance with DIN 18032 part 3 and fulfils the demands for handball ball throwing (restrictedly safe against ball throwing).
Rockfon VertiQ A mounted in Rockfon System VertiQ HAT A Wall has been tested for impact resistance in accordance with DIN 18032 part 3 and fulfils the demands for handball ball throwing (restrictedly safe against ball throwing).
Rockfon System VertiQ HAT A Wall gives additional protection of Rockfon VertiQ A panels by HAT steel profile and can be used in areas subjected to occasional impact.
The impact resistance of Rockfon System VertiQ HAT A Wall and Rockfon System VertiQ C Wall is high, however, it is not recommended for use in areas which are subjected to continuous high levels of impact.
The woven surface of Rockfon VertiQ panels provides enhanced resistance to perforation, tested in accordance with NF P 08-301.,
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back
Back

Downloads

documents

 

 

pdf
Rockfon VertiQ® | Datasheet
Rockfon VertiQ® | Datasheet

pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
DoP-RFN-0129-041-4 - Rockfon VertiQ®
DoP-RFN-0129-041-4 - Rockfon VertiQ®

pdf
Back